Flow Coil

SPIF

For the embolization of vascular malformations in neurological and peripheral regions.

Properties

Unique nano-platinum coil that can be injected via a 1.2F catheter (flow-coil).

 

  • Suitable for the “Pressure Cooker Technique” (*)
  • Primary winding of .007"
  • Available in lengths from 5 cm up to 20 cm

 

Website

www.balt-corp.com

Specifications
Relevant products

Baltacci

Intracerebral microinfusion catheter

Reinforced flow-guided 1.2F/1.5F/1.8F microcatheter for the treatment of cerebral AVM.

Magic

Microcatheter

Microcatheter for selective and hyperselective catheterization for diagnostics and therapy.

Sonic

Microcatheter

Microcatheter for selective and hyperselective catheterization for diagnostics and therapy.
Related products

Magic Glue

Liquid Embolic

Liquid acrylate for embolization of arteriovenous malformations (AVM) in peripheral, intra- and extracranial vessels.

Squid

Liquid Embolic

Ethylene vinyl alcohol copolymer (EVOH) based liquid embolic dissolved in DMSO.
Videos
Legal information

(*) Chapot et al., (2014) The Pressure Cooker Technique for the treatment of brain AVMs

The occlusion devices Flow Coils are intended for the embolization of vascular malformations of the vasculature. Class III CE0297 in compliance with Medical Device Directive (MDD 93/42/EEC amended by 2007/47/EC). Manufactured by BALT EXTRUSION SAS. Carefully read the instructions for use before use. French reimbursement codes 3123690. First CE marking:2008. MAGIC is a microcatheter intended for selective and hyperselective vascular catheterization for diagnostic and therapeutic purposes. Class III CE0297 in compliance with Medical Device Directive (MDD 93/42/EEC amended by 2007/47/EC). Manufactured by BALT EXTRUSION SAS. Carefully read the instructions for use before use. Not reimbursed. First CE marking:1998. SONIC is a braided microcatheter intended for selective and hyper selective vascular catheterization for diagnostic and therapeutic purposes. Class III CE0297 in compliance with Medical Device Directive (MDD 93/42/EEC amended by 2007/47/EC). Manufactured by BALT EXTRUSION SAS. Carefully read the instructions for use before use. Not reimbursed. First CE marking:2005. VASCO+ is a reinforced microcatheter intended for injection or diagnostic or therapeutic products; to position pushable coils “SPIRALES” or detachable coils especially the ones of MDS “mechanical detachment system”; for the use of the self-expanding stent LEO+ or SILK+. Class III CE0297 in compliance with Medical Device Directive (MDD 93/42/EEC amended by 2007/47/EC). Manufactured by BALT EXTRUSION SAS. Carefully read the instructions for use before use. Not reimbursed. First CE marking:2004. BALTACCI microcatheter is intended for selective and hyperselective vascular catheterization for diagnostic and therapeutic purposes. Class III CE0297 in compliance with Medical Device Directive (MDD 93/42/EEC amended by 2007/47/EC). Manufactured by BALT EXTRUSION SAS. Carefully read the instructions for use before use. Not reimbursed. First CE marking:1998. The content of this document, in particular data, information, trademarks and logo is BALT SAS and affiliates’ sole property. ©2020 BALT SAS and affiliates, all rights reserved. All representation and/or reproduction, whether in part or in full, is forbidden and would be considered a violation of BALT SAS and affiliates’ copyrights and other intellectual property rights. This document with associated pictures is non contractual and is solely dedicated to healthcare professionals and BALT’s distributors (BALT’s supplier’s distributors). The products commercialized by BALT shall exclusively be used in accordance with the instructions for use included in the box.