Microcatheter

Gama17

Our allrounder: .017“ microcatheter

Properties

The GAMA17 is designed for the injection of diagnostic or therapeutic products and is compatible with pushable or detachable coils. It also is indicated for the implantation of compatible intracranial self-expanding stents and flow-diverters, as well as for the use of compatible stent retrievers.

 

  • Easy navigation due to hydrophilic coating and different flexible sections
  • Maximised stability (8 flattened nitinol wires combined with a steel filament)
  • Lined with a novel PTFE-coating for frictionless application of compatible systems
  • DMSO-compatible
  • .017" I.D.

 

Website

www.balt-corp.com

Specifications
Relevant products

Silk Vista Baby

Flow-Diverter

Haemodynamically effective implant for the endovascular treatment of intracranial aneurysms and brain-supplying cervical vessels.

Leo+ Baby

Stent

Intracranial self-expanding microstent.

Catch View

Stentretriever

For recanalization in patients with ischaemic stroke due to intracranial vessel occlusion.

Optima

Coil

Detachable Coil System.
Related products

Vasco+

Microcatheter

Intracerebral microcatheter.

Hybrid

Guide wire

The microguidewires combine a distal nitinol core and a proximal steel component.

RYVA / ANRYV

Y-Connectors

Y-Connector resistant to high pressure.
Videos
Legal information

The Gama reinforced microcatheters are intended for use in interventional radiology procedures in the vascular and neurovascular system for: the injection of diagnostic or therapeutic products, the insertion of compatible pushable coils or detachable coils, the insertion of compatible intracranial self-expandable stents, the insertion of compatible thrombo-embolectomy devices. Class III CE0297 in compliance with Medical Device Directive (MDD 93/42/EEC amended by 2007/47/EC). Manufactured by BALT EXTRUSION SAS. Carefully read the instructions for use before use. First CE-Mark: 2019. CATCH+ and CATCHView are designed for use in the flow restoration of patients with ischemic stroke due to large intracranial vessel occlusion. They are indicated to restore blood flow in the neurovasculature of patients who are ineligible for intravenous tissue plasminogen activator (IV t-PA), who fail IV t-PA therapy or as a supplement treatment of initiated IV t-PA therapy. The CATCH+ and CATCHView thromboembolectomy devices should only be used by physicians trained in interventional neuroradiology and treatment of ischemic stroke. Class III CE0297 in compliance with Medical Device Directive (MDD 93/42/EEC amended by 2007/47/EC). Manufactured by BALT EXTRUSION SAS. Carefully read the instructions for use before use. Not reimbursed. First CE marking: 2012 (CATCH+), 2018 (CATCHView). The self-expandable LEO+/LEO+ Baby stent is designed for the treatment of intracranial aneurysms in association with embolization coils. Class III CE0297 in compliance with Medical Device Directive (MDD 93/42/EEC amended by 2007/47/EC). Manufactured by BALT EXTRUSION SAS. Carefully read the instructions for use before use. First CE marking: 2007 (LEO+), 2012 (LEO+ Baby). The self-expandable SILK Vista Baby are designed for the treatment of intracranial aneurysms. Class III CE0297 in compliance with Medical Device Directive (MDD 93/42/EEC amended by 2007/47/EC). Manufactured by BALT EXTRUSION SAS. Carefully read the instructions for use before use. Not reimbursed. First CE marking: 2012. The Optima Coil System is intended for use in the peripheral and neurovasculature to endovascularly obstruct or occlude blood flow in vascular abnormalities of the neurovascular and peripheral vessels. Class III CE0297 in compliance with Medical Device Directive (MDD 93/42/EEC amended by 2007/47/EC). Manufactured by BALT USA LLC. Carefully read the instructions for use before use. First CE marking: 2017. The content of this document, in particular data, information, trademarks and logos is BALT SAS and affiliate’s sole property. ©2019 BALT SAS and affiliates, all rights reserved. All representation and/or reproduction, whether in part or in full, is forbidden and would be considered a violation of BALT SAS and affiliates’ copyrights and other intellectual proprietary rights. This document with associated pictures is non-contractual and is solely dedicated to healthcare professionals and BALT’s distributors (BALT’s supplier’s distributors). The products commercialized by BALT shall exclusively be used in accordance with the instructions for use included in the boxes.