Double-lumen balloon catheter

Eclipse 2L

Double-lumen balloon catheter for remodeling, vasospasm therapy or temporary occlusion.

Properties

The unique "Flat-Catheter-Concept" allows a fast filling and deflation of the balloon, even with concentrated contrast medium mixtures. In addition, this new development permits the simultaneous use of the balloon with a coiling catheter in a 6F guiding catheter.

 

  • New "Flat-Catheter-Concept" (FCC)
  • .017" working channel allows implantation of Leo Baby Stent or Silk Vista Baby flow-diverter
  • Largest choice of available lengths on the market
  • Rapid inflation and deflation of the balloon
  • DMSO-compatible

 

Website

www.balt-corp.com

Specifications
Relevant products

Leo+ Baby

Stent

Intracranial self-expanding microstent.

Silk Vista Baby

Flow-Diverter

Haemodynamically effective implant for the endovascular treatment of intracranial aneurysms and brain-supplying cervical vessels.

Optima

Coil

Detachable Coil System.

Hybrid

Guide wire

The microguidewires combine a distal nitinol core and a proximal steel component.
Related products

Copernic 2L

Double-lumen balloon catheter

For use in cerebral and peripheral vessels for remodeling and temporary occlusion.

Copernic & Eclipse

Balloon catheter

Mono-lumen balloon catheters for remodeling, vasospasm therapy or temporary occlusion.
Videos
Legal information

ECLIPSE 2L is a double lumen balloon catheter intended for use in the peripheral vasculature and neurovasculature for temporary occlusion. The balloon catheters provide temporary vascular occlusion which is useful in selectively stopping or controlling blood flow and for the vasospasm treatment. The balloon catheters also offer balloon assisted embolization of intracranial aneurysms. They are also indicated for use in the peripheral vasculature and neurovasculature for administration of diagnostic agents (contrast solution) and therapeutic agents (embolization materials compatible with the inner diameter of the balloon catheters ECLIPSE 2L). Class III CE0297 in compliance with Medical Device Directive (MDD 93/42/EEC amended by 2007/47/EC). Manufactured by BALT Extrusion. Carefully read the instructions for use before use. First CE marking:2014.

The content of this document, in particular data, information, trademarks and logos are BALT SAS’s sole property. © 2018 year BALT and its affiliates, all rights reserved. All representation and/or reproduction, whether in part or in full, is forbidden and would be considered a violation of BALT SAS and its affiliates’ copyrights and other intellectual proprietary rights. This document with associated pictures are non-contractual and are solely dedicated to healthcare professionals and BALT’s distributors (BALT’s supplier’s distributors). The products commercialized by BALT SAS shall exclusively be used in accordance with the instructions for use included in the boxes.

Inquiry
Privacy Policy*
Please add 5 and 8.