Double-lumen balloon catheter

Copernic 2L

For use in cerebral and peripheral vessels for remodeling and temporary occlusion.

Properties

The double-lumen balloon is used for balloon-protected coiling of aneurysms (remodeling). A particular advantage is that it can be used with a working channel of .024" to deliver a Leo stent, for example. This allows users to implant a stent without changing manoeuvres.

 

  • Unique "Flat Catheter Concept" (FCC)
  • Working channel of .024" for Leo stent delivery and implantation
  • Rapid inflation and deflation of the balloon
  • DMSO-compatible

 

Website

www.balt-corp.com

Specifications
Relevant products

Leo+

Stent

Intracranial self-expanding stent.

Squid

Liquid Embolic

Ethylene vinyl alcohol copolymer (EVOH) based liquid embolic dissolved in DMSO.
Related products

Optima

Coil

Detachable Coil System.

Leo+

Stent

Intracranial self-expanding stent.

Leo+ Baby

Stent

Intracranial self-expanding microstent.

Silk Vista

Flow-Diverter

Haemodynamically effective implant for the endovascular treatment of intracranial aneurysms and brain-supplying cervical vessels.

Silk Vista Baby

Flow-Diverter

Haemodynamically effective implant for the endovascular treatment of intracranial aneurysms and brain-supplying cervical vessels.
Videos
Legal information

The COPERNIC 2L double lumen balloon catheters are intended for use in the peripheral vasculature and neurovasculature for temporary occlusion. The balloon catheters provide temporary vascular occlusion which is useful in selectively stopping or controlling blood fl ow and for the vasospasm treatment. The balloon catheters also offer balloon assisted embolization of intracranial aneurysms. They are also indicated for use in the peripheral vasculature and neurovasculature for administration of diagnostic agents (contrast solution) and therapeutic agents (embolization materials compatible with the inner diameter of the balloon catheters COPERNIC 2L).

The content of this document, in particular data, information, trademarks and logos are BALT S.A.S and affiliates’ sole property. Consequently, all representation and/ or reproduction, whether in part or in full, is forbidden and would be considered a violation of BALT S.A.S and affiliates’ copyrights and other intellectual proprietary rights ©2017 BALT S.A.S and affiliates all rights reserved. This document with associated pictures are non-contractual and are solely dedicated to healthcare professionals and BALT S.A.S and affiliates’ distributors. The products commercialized by BALT SAS and affiliates shall exclusively be used in accordance with the package inserts which have been updated and included in the boxes. COPERNIC 2L is class III CE marked (LNE/G-MedCE0459) according to the Medical Device Directive 93/42/EEC since 2014.